Serpens Main Trial 2D Flags

From CARMA
(Difference between revisions)
Jump to: navigation, search
Line 15: Line 15:
 
'''manuel'''
 
'''manuel'''
 
   
 
   
  * i didn't see high gains on c18 (refant 8)
+
  * Agree essentially with John
  * #No coherence on C16
+
* but I didn't see high gains on c18 (I used refant=8)
 +
  * I see some bad amplitudes and phases in 3c279 related to C1, C14 and C18, but I didn't flag them.
 +
* uvflag vis=uvdata_cp flagval=flag select="ant(16)" #No coherence on C16
 +
* uvflag vis=uvdata_cp flagval=flag select="source(3c279),ant(1,18),time(08:51,08:53)" # bad Rxstate
 +
* uvflag vis=uvdata_cp flagval=flag select="source(1743-038),ant(4,5),time(09:30,09:38)" # high gains
 +
* uvflag vis=uvdata_cp flagval=flag select="source(1743-038),ant(1,4,5,8,9,11,13,14,15,19),time(10:37,10:41)" # high gains
 +
* uvflag vis=uvdata_cp flagval=flag select="source(1743-038,serpm),ant(7,22),time(14:20,15:00)" # high gains

Revision as of 15:59, 25 April 2012

  • C1 and C18 bad RxState first ~1-2 minutes of 3c279 observation


John

MWC349 is missing from the track.

#antenna 18 has high gains across the entire track
#high gains at end of track
ant(7,22),time(14:11:38.5,14:29:38.5),source(1743-038,SERPM)
# low amp on band pass calibrator integration
ant(1),time(08:51:46.5,08:53:00),source(3C279)

manuel

* Agree essentially with John
* but I didn't see high gains on c18 (I used refant=8)
* I see some bad amplitudes and phases in 3c279 related to C1, C14 and C18, but I didn't flag them.
* uvflag vis=uvdata_cp flagval=flag select="ant(16)" #No coherence on C16
* uvflag vis=uvdata_cp flagval=flag select="source(3c279),ant(1,18),time(08:51,08:53)" # bad Rxstate
* uvflag vis=uvdata_cp flagval=flag select="source(1743-038),ant(4,5),time(09:30,09:38)" # high gains
* uvflag vis=uvdata_cp flagval=flag select="source(1743-038),ant(1,4,5,8,9,11,13,14,15,19),time(10:37,10:41)" # high gains
* uvflag vis=uvdata_cp flagval=flag select="source(1743-038,serpm),ant(7,22),time(14:20,15:00)" # high gains