Serpens Main Trial 1E Flags

From CARMA
Jump to: navigation, search

Notes

obs

2012-07-04              c0924I.3E_88Serpen.1   4.2  B-
                               Comments:
                                NODE_NOT_FOUND
                                [2012-07-04 10:30]DR : Bandpass solution is bad, probably
                               because the bandpass calibrator is too weak. Grade was
                               decreased to B-

shaye

* 1743-038 observed for BP possibly because it is brighter than the one "preferred" calibrator that were up at the start of the track. 
* We probably will need to use the noise source to bp calibrate this track, and the D array tracks that did not get 3c279.

manuel

* c10, c15: no neptune data
* c13,c14: some missing integrations on 1743-038 at the end of the track
* c21: 1743-038 possibly shadowed in the middle of the track
* ovro-C21 baselines: low SNR for bpass

Flags

Shaye

 select='ant(4),time(06:15:51.8,07:02:01)' flagval=f 
 select='ant(15),time(05:07:00,05:47:01.0)' flagval=f

Manuel

 select='ant(4),time(06:36:00,06:39:00),source(1743-038)' flagval=f  # Tsys outliers on 1743-038
 select='ant(10),time(06:15:51.8,07:01:12.0)' flagval=f # Jump in Tsys spans 1743-038 and Serpens integrations
 select='ant(15),time(05:00:00.0,05:46:13.5)' flagval=f # Bad tsys 2 first 1743-038 integrations
 select='ant(14),time(08:11:41.8,09:12:21.5)' flagval=f # shadowed calibrator???
 select='ant(21),time(06:41:01.8,08:30:47.5)' flagval=f # Shadowed calibrator???