NAME

uvclip - Determine data to flag from channel-0 uv dataset  

PERSON RESPONSIBLE

njt  

CATEGORIES

uv analysis  

DESCRIPTION

UVCLIP flags UV channel 0 data set by statistical clipping  

PARAMETERS

vis
The input UV dataset name. No default.
select
This selects the data to be processed, using the standard uvselect format. Default is all data.
options
noamp .... no visbility amplitude clipping notrip ... no triple visibility phase closure clipping doall .... include all data (flagged and unflagged) noapply .. do not apply flagging
interval
Data clipping interval in minutes. The maximum interval between data points for continuous clipping. Must be greater than the integration time. The default is infinite.
clip
Clipping level. Number of rms beyond which data is flagged. Default is 3.
log
The list output file name. The default is the terminal.


 